Chapter 3: Programming
56 Concord 4 Installation Manual
Timers - partition 1 to 6 settings
Entry delay
Shortcut: 0310 to 0360
Default: 30 seconds
This setting determines how much time you have to disarm the system
(after entering the armed premises through a designated delay door)
without causing an alarm (30 to 240 seconds).
Exit delay
Shortcut: 0311 to 0361
Default: 60 seconds
This setting determines how much time you have (after arming the system)
to leave the premises through a designated delay door without causing an
alarm (45 to 184 seconds).
Extended delay
Shortcut: 0312 to 0362
Default: 4 minutes
This setting determines how much time you have (after arming the system)
to enter or exit the premises through a designated extended delay door (1
to 8 minutes).
Siren timeout
Shortcut: 0313 to 0363
Default: 4 minutes
This setting determines how long sirens sound (1 to 30 minutes) if no one is
present to disarm the system.
Sleep time
Shortcut: 0314 to 0364
Default: 22:00 (10:00
p.m.)
This setting determines the start time and restart of a 10-hour window
during which trouble beeps are suppressed (00:00 to 23:50 using 10 minute
intervals). The initial occurrence of an event that causes trouble beeps
within this window does not sound trouble beeps until the sleep time
window expires. If trouble beeps from a previous event are due to be
restarted during the sleep time window, they restart one hour prior to sleep
time.
To turn off sleep time, with the display showing SLEEP TIME hh:mm
(current setting), press D.
No usage time
Shortcut: 0315 to 0365
Default: None
This setting determines how many days (2 to 255) a partition can remain
disarmed before the panel sends a no usage report to the central
monitoring station and stores the event in the history buffer.
When this feature is set:
• This timer decreases by one at sleep time each day the selected partition
remains disarmed.
• If the timer gets to 0 at sleep time, the panel sends a no usage report to
the central monitoring station and stores the event in the history buffer.
• If the partition is armed before the timer reaches 0, the timer resets to the
programmed setting.
When this feature is not set (default), the panel does not send or log no
usage reports.
To turn off no usage time, with the display showing NO USAGE TIME
(current setting), press D.