EasyManuals Logo

GE Concord 4 Installation Manual

GE Concord 4
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
Chapter 3: Programming
62 Concord 4 Installation Manual
Reporting - partition 1 to 6 settings
Opening reports
Shortcut: 06100 to
06600
Default: Off
When this setting is on, the panel sends an opening report to the central
station after disarming the system.
To use this feature, the open/close reports settings under the “
Phones
menu”
on page 48 must be turned on for the specific CS phone or pager
number.
Closing reports
Shortcut: 06101 to
06601
Default: Off
When this setting is on, the panel sends a closing report to the central
station after arming the system.
To use this feature, the open/close reports settings under the “
Phones
menu”
on page 48 must be turned on for the specific CS phone or pager
number.
No activity option
Shortcut: 06102 to
06601
Default: Off
When this setting is on, the panel sends a no activity report to the central
station when the activity timeout expires.
Duress option
Shortcut: 06103 to
06603
Default: Off
When this setting is on, the system can be controlled using a
programmed duress code (see “
Security - partition 1 to 6 setting” on page
47) and will send a duress alarm to the monitoring station.
Do not use a duress code unless it is necessary. Using duress codes often
results in false alarms due to code entry errors. If a duress code is
necessary, use it with the audio verification module to reduce false
alarms and accidental dispatches. The audio verification module is listen
only.
Force armed
Shortcut: 06104 to
06604
Default: Off
When this setting is on, the panel reports to the central monitoring station
when you “force arm” the system.
Forced arming occurs if you press Bypass when arming the system with
open sensors/zones protesting. Auto-forced arming occurs when you do
not press Bypass when arming the system with open sensors/zones
protesting, and then leave through an entry/exit door and the arming
protest period expires. This causes the system to automatically bypass
the open (protesting) sensors. Auto-forced arming always reports to the
central monitoring station.

Table of Contents

Other manuals for GE Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 and is the answer not in the manual?

GE Concord 4 Specifications

General IconGeneral
Zones96
Partitions6
User Codes230
Power Supply16.5 VAC, 40 VA
Wireless CompatibilityCompatible with GE wireless sensors
KeypadsUp to 8
Outputs2 onboard, expandable
Event Log512 events
Backup Battery12VDC, 7AH
CommunicationPhone line, optional cellular or IP