6 - 28 Reference and Specification
K0260 Issue No. 8
2. Use the Up and Down keys to highlight the required aeronautical and pressure units.
3. Press SAVE SETTINGS to store in non-volatile memory or press MAIN MENU to store in volatile memory
and return to the Main Menu Screen. Press RESTORE DEFAULTS to restore the last set of stored values
and unit selection saved as a default.
Select limits
Enter the PIN to access the SETUP LIMITS
display. Select one of the preset limits of MAX,
STANDARD and CIVIL or define and enable USER
1 limits. An eight character name/code can
replace USER 1 title.
Default limits
This set of limits, identified as: CIVIL are enabled
when the ADTS 505 is switched on:
MIN ALT -1000 ft
MAX ALT 50,000 ft
MIN CAS 0.0 knots
MAX CAS 450 knots
MAX MACH 1.0 Mach
MAX ROC 6,000 ft/min
ARINC LIMITS OFF
ALT CORRECTION 0 ft
MIN Ps 115.972 mbar (2.7 inHg)
MAX Ps 1050.406 mbar (38.1000 inHg)
MIN Qc 0.0 mbar
MAX Qc 368.01 mbar (10.8673 inHg)
MAX Rate Ps 109.85 mbar/min (10.8127 inHg/min)
MAX Rate Qc 109.85 mbar/min (10.8127 inHg/min)