16–8 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
SNMP CHAPTER 16: SNMP
Configuring SNMP (continued)
ML1200(snmpv3)##
trap add id=1 type=v1 host=3.94.200.107
Entry is added successfully
ML1200(snmpv3)## show-trap
ID Trap Type Host IP Community Port
================================================
1 v1 3.94.200.107 -- --
2---- ----
3---- ----
4---- ----
5---- ----
ML1200(snmpv3)## show-trap id=1
Trap ID : 1
Trap Type : v1
Host IP : 3.94.200.107
Community : --
Auth. Type : --
ML1200(snmpv3)##
com2sec add id=1 secname=public source=default c
Entry is added successfully
ML1200(snmpv3)## com2sec add id=2
ERROR: "secname" parameter is required for "add" directive
ML1200(snmpv3)## com2sec add id=2 secname=BCM
Entry is added successfully
ML1200(snmpv3)## show-com2sec
ID Sec. Name Source Community
=============================================
1 public default public
2 BCM default public
3-- -- --
4-- -- --
5-- -- --
6-- -- --
7-- -- --
8-- -- --
9-- -- --
10 -- -- --
ML1200(snmpv3)## show-com2sec id=2
Com2Sec ID : 2
Security Name : BCM
Source : default
Community : public
ML1200(snmpv3)## group add id=1 groupname=v1 model=v1 com2secid=1
Entry is added successfully
(continued on next page)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MultiLink ML1200 and is the answer not in the manual?

GE MultiLink ML1200 Specifications

General IconGeneral
BrandGE
ModelMultiLink ML1200
CategorySwitch
LanguageEnglish

Related product manuals