EasyManuals Logo

GE MultiLink ML1200 User Manual

GE MultiLink ML1200
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #319 background imageLoading...
Page #319 background image
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOL
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL 18–29
0588 Port 25: Number of bytes sent 0 to
4294967295
1F9 0
058A Port 25: Number of frames received 0 to
4294967295
1F9 0
058C Port 25: Number of frames sent 0 to
4294967295
1F9 0
058E Port 25: Total bytes received 0 to
4294967295
1F9 0
0590 Port 25: Total frames received 0 to
4294967295
1F9 0
0592 Port 25: Number of broadcast frames
received
0 to
4294967295
1F9 0
0594 Port 25: Number of multicast frames
received
0 to
4294967295
1F9 0
0596 Port 25: Number of frames with CRC
error
0 to
4294967295
1F9 0
0598 Port 25: Number of oversized frames
received
0 to
4294967295
1F9 0
059A Port 25: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
059C Port 25: Number of jabber frames
received
0 to
4294967295
1F9 0
059E Port 25: Number of collisions occurred 0 to
4294967295
1F9 0
05A0 Port 25: Number of late collisions
occurred
0 to
4294967295
1F9 0
05A2 Port 25: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
05A4 Port 25: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1F9 0
05A6 Port 25: Number of 128 to 255 byte
frames received/sent
0 to
4294967295
1F9 0
05A8 Port 25: Number of 256 to 511 byte
frames received/sent
0 to
4294967295
1F9 0
05AA Port 25: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1F9 0
05AC Port 25: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
05AE Port 25: Number of MAC error packets 0 to
4294967295
1F9 0
05B0 Port 25: Number of dropped received
packets
0 to
4294967295
1F9 0
05B2 Port 25: Number of multicast frames
sent
0 to
4294967295
1F9 0
05B4 Port 25: Number of broadcast frames
sent
0 to
4294967295
1F9 0
05B6 Port 25: Number of <64 byte fragments
with good CRC
0 to
4294967295
1F9 0
05B8 Port 26: Number of bytes received 0 to
4294967295
1F9 0
05BA Port 26: Number of bytes sent 0 to
4294967295
1F9 0
05BC Port 26: Number of frames received 0 to
4294967295
1F9 0
05BE Port 26: Number of frames sent 0 to
4294967295
1F9 0
Table 18–1: Modbus memory map (Sheet 26 of 33)
Address Description Range Step Format Default

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MultiLink ML1200 and is the answer not in the manual?

GE MultiLink ML1200 Specifications

General IconGeneral
BrandGE
ModelMultiLink ML1200
CategorySwitch
LanguageEnglish

Related product manuals