18–32 MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
MODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL
0630 Port 28: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
0632 Port 28: Number of jabber frames
received
0 to
4294967295
1F9 0
0634 Port 28: Number of collisions occurred 0 to
4294967295
1F9 0
0636 Port 28: Number of late collisions
occurred
0 to
4294967295
1F9 0
0638 Port 28: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
063A Port 28: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1F9 0
063C Port 28: Number of 128 to 255 byte
frames received/sent
0 to
4294967295
1F9 0
063E Port 28: Number of 256 to 511 byte
frames received/sent
0 to
4294967295
1F9 0
0640 Port 28: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1F9 0
0642 Port 28: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
0644 Port 28: Number of MAC error packets 0 to
4294967295
1F9 0
0646 Port 28: Number of dropped received
packets
0 to
4294967295
1F9 0
0648 Port 28: Number of multicast frames
sent
0 to
4294967295
1F9 0
064A Port 28: Number of broadcast frames
sent
0 to
4294967295
1F9 0
064C Port 28: Number of <64 byte fragments
with good CRC
0 to
4294967295
1F9 0
064E Port 29: Number of bytes received 0 to
4294967295
1F9 0
0650 Port 29: Number of bytes sent 0 to
4294967295
1F9 0
0652 Port 29: Number of frames received 0 to
4294967295
1F9 0
0654 Port 29: Number of frames sent 0 to
4294967295
1F9 0
0656 Port 29: Total bytes received 0 to
4294967295
1F9 0
0658 Port 29: Total frames received 0 to
4294967295
1F9 0
065A Port 29: Number of broadcast frames
received
0 to
4294967295
1F9 0
065C Port 29: Number of multicast frames
received
0 to
4294967295
1F9 0
065E Port 29: Number of frames with CRC
error
0 to
4294967295
1F9 0
0660 Port 29: Number of oversized frames
received
0 to
4294967295
1F9 0
0662 Port 29: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
0664 Port 29: Number of jabber frames
received
0 to
4294967295
1F9 0
0666 Port 29: Number of collisions occurred 0 to
4294967295
1F9 0
Table 18–1: Modbus memory map (Sheet 29 of 33)
Address Description Range Step Format Default

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MultiLink ML1200 and is the answer not in the manual?

GE MultiLink ML1200 Specifications

General IconGeneral
BrandGE
ModelMultiLink ML1200
CategorySwitch
LanguageEnglish

Related product manuals