10
This table shows typical connections. OEMs may have a different connection scheme.
Connecting high voltage accessories: North American model in.yj
Wires to connect high voltage accessories must have 0.25” quick-connect terminals.
These tabs require high-voltage accessories to have straight, non-insulated, female quick-connect terminals for all
connections, including ground. Depending on where the connections are made on the in.yj pack PCB, 120 V and 240 V
accessories are supported. Refer to the following tables for correct connections. Note that all female terminals must be
correctly and completely seated on the PCB tab for proper current ratings.
Direct output
Voltage 120 V 240 V
Green / ground P27 P27
Black / line P25 P25
White / common P18 P14
Pump 1
Voltage 120 V 240 V
Green / ground P28 P28
Black / low speed K6-P K6-P
Red / high-speed K7-P K7-P
White / common P19 P15
Make sure all accessories are linked to the bonding lug connector located on the side of the spa pack.
Connections
Heat.wav-yj
Green / ground P5
Black / line P3
White / common P4
Ozone
(Working with pump 1 low speed)
Voltage 120 V 240 V
Green / ground P30 P30
Black / line P23 P23
White / common P35 P37
Light (12 V DC , 500mA)
Switch P33
Pump 2 (in.yj-3 only)
Voltage 120 V 240 V
Green / ground P29 P29
Black / low speed K5-P K5-P
White / common P20 P16