ADV200 Functions description and parameters list 171
This parameter is active when the speed is below the threshold set in parameter 940Speed0threshold.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
946 Speedis0delay BIT 16 0 0 1 ER
This signal is active when the reference is below the threshold set in parameter940Speed0threshold. The
signal is activated after the delay set in parameter 942Speed0delay.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
956 Speedthr1_2mon BIT 16 0 0 1 ER
To display the speed threshold status: if the motor speed is higher than the value set in parameter 950 Speed
threshold1 or lower than the value set in parameter 952Speedthreshold2 this parameter assumes the
value of 0.
If the motor speed is between the value of 950 Speedthreshold1 and that of 952Speedthreshold2, this
parameter assumes the value of 1.
Use parameter 954Speedthresholddly to set a delay time for the transition from 0 to 1 of parameter 956
Speedthr1_2mon; the transition from 1 to 0 is always immediate.
When 950 Speedthreshold1 is set to a value higher than 952Speedthreshold2, if the motor speed is be-
tween the thresholds this parameter assumes the value of 1. If 950 Speedthreshold1 is set to a value lower
than 952Speedthreshold2, the threshold status is not signicant
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
966 Setspeed BIT 16 0 0 1 ER
This signal is active when the error between the speed reference and actual motor speed is greater than the
tolerance set in parameter 962Setspeederror.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
976 Speedthr3mon BIT 16 0 0 1 ER
The status of the block that detects exceeding of the speed 3 threshold is displayed.
0 Actual speed below threshold
1 Actual speed above threshold
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
986 Currentthrmon BIT 16 0 0 1 ER
The status of the block that detects exceeding of the current threshold is displayed.
0 Actual output current below threshold
1 Actual output current above threshold.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1030Local/remotemon BIT 16 0 0 1 ER
This signal is active when the drive is in the Remote operating mode.
0 Local
1 Remote
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1060Sequencerstatus UINT16 16 0 0 0 ER
This signal indicates the state of the “machine states” that controls drive operation.
STS_INIT 0
STS_MAGN 1
STS_STOP 2
STS_START 3
STS_FS_STOP 4

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals