256 ADV200 Parameters List
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
0 Disable
1 Enable
24.5 4508 ExtFlt restart time ms UINT16 1000 120 30000 RW FVS
24.6 4510 ExtFlt holdoff ms UINT16 0 0 10000 RW FVS
24.7 4516 MotorOT pre activity ENUM Ignore 0 4 ERW FVS
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop
24.8 4518 MotorOT pre thr perc UINT16 60 0 100 ERW FVS
24.9 4520 MotorOT src LINK 16BIT 6000 0 16384 RW FVS
L_DIGSEL2
24.10 4522 MotorOT activity ENUM Warning 0 4 RW FVS
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop
24.11 4524 MotorOT restart ENUM Disable 0 1 RW FVS
0 Disable
1 Enable
24.12 4526 MotorOT restart time ms UINT16 1000 120 30000 RW FVS
24.13 4528 MotorOT holdoff ms UINT16 1000 0 30000 RW FVS
24.14 4530 MotorOT probe ENUM SRC 0 8 ERW FVS
0 SRC
1 Sens An1X
2 Sens An2X
3 KTY84 AnX
4 PTC AnX
5 KTY84 An1
6 KTY84 An2
7 PTC An1
8 PTC An2
24.15 4532 MotorOT thr cnt UINT16 0 0 32767 ERW FVS
24.16 4536 MotorOT mon cnt INT16 0 0 32767 ER FVS
24.17 4540 Overspeed threshold rpm INT32 CALCI 0 CALCI RW FVS
24.18 4542 Overspeed activity ENUM Disable 0 4 RW FVS
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop
24.19 4544 Overspeed holdoff ms UINT16 0 0 5000 RW FVS
24.20 4550 SpdRefLoss threshold rpm INT16 100 0 CALCI RW FVS
24.21 4552 SpdRefLoss activity ENUM Ignore 0 4 RW FVS
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast stop
24.22 4554 SpdRefLoss holdoff ms UINT16 1000 0 10000 RW FVS
24.23 4560 SpdFbkLoss activity ENUM Disable 0 4 RW FV_