Installation Guidelines
60 Hz Air-Cooled Generators
15 kW EcoGen™
SAVE THIS MANUAL FOR FUTURE REFERENCE
Para español, visita: http://www.generac.com/service-support/product-support-lookup
Pour le français, visiter : http://www.generac.com/service-support/product-support-lookup
(000209a)
WARNING
This product is not intended to be used in
a critical life support application. Failure to
adhere to this warning could result in
death or serious injury.
Register your Generac product at:
WWW.GENERAC.COM
1-888-GENERAC
(888-436-3722)

Table of Contents

Questions and Answers

  • B
    briana68Aug 10, 2025
    What to do if my Generac Power Systems EcoGen G0070340 Portable Generator has no AC output?
    • V
      Valerie GonzalezAug 10, 2025
      If there is no AC output from your generator, first check if the main line circuit breaker is in the OFF (or OPEN) position. If it is, reset the circuit breaker to ON (or CLOSED). If the problem persists, it may indicate a generator internal failure.
  • J
    jonathanaguilarAug 15, 2025
    Why won't my Generac Power Systems EcoGen G0070340 Portable Generator engine crank?
    • J
      Jamie VaughnAug 15, 2025
      If your engine won't crank, here are a few things to check: 1. A blown fuse could be the culprit. Correct any short circuit conditions and replace the 7.5 Amp fuse. 2. Inspect battery cables for looseness, corrosion, or defects. Tighten, clean, or replace them as needed. 3. Check for a defective starter contact or starter motor. Tighten, clean, or replace if necessary. 4. The battery might be dead. Try charging or replacing it.
  • T
    Timothy HarrisonAug 19, 2025
    What to do if my Generac Power Systems Portable Generator engine cranks but won't start?
    • A
      Antonio FergusonAug 19, 2025
      If your Generac Power Systems Portable Generator engine cranks but doesn't start, consider these possibilities: * The generator may be out of fuel. Replenish the fuel and ensure the fuel valve is turned on. * There might be defective spark plugs. Clean, check the gap, or replace the spark plug(s). * The valve clearance may need adjustment. Adjust the valve clearance. * The fuel pressure might be too high. Verify correct fuel pressure.
  • L
    Lauren MccoyAug 26, 2025
    Why does my Generac Power Systems Portable Generator start hard and run rough?
    • A
      Alicia SmithAug 26, 2025
      If your Generac Power Systems Portable Generator starts hard and runs rough, the following could be the reasons: * The air cleaner might be plugged or damaged. Check and replace the air cleaner if needed. * The spark plugs could be defective. Clean, check the gap, or replace the spark plug(s). * The fuel regulator may not be set correctly. Set the fuel regulator. * The fuel pressure might be incorrect. Confirm the fuel pressure to the regulator is 10–12 in. water column (19–22 mm mercury) for LP, and 3.5–7 in. water column (7–13 mm mercury) for natural gas. * The fuel selector might be in the wrong position. Move the selector to the correct position.
  • K
    Katherine BakerAug 30, 2025
    What to do if Generac Power Systems EcoGen G0070340 Portable Generator is set to OFF, but the engine continues to run?
    • J
      Jordan WalkerAug 30, 2025
      If your generator is set to OFF, but the engine continues to run, it could be due to: * A control board wired incorrectly. Repair the wiring or replace the control board. * A defective control board. Replace the control board.
  • G
    gonzalesbrendaSep 4, 2025
    Why does my Generac Power Systems EcoGen G0070340 consume large amounts of oil?
    • J
      Jaime LeSep 4, 2025
      If your unit consumes large amounts of oil, consider the following: * The oil tank may be overfilled. Adjust the oil to the proper level. * It could be due to improper type or viscosity of oil. See Engine Oil Recommendations for guidance. * A damaged gasket, seal, or hose may be present. Check for oil leaks.

Generac Power Systems EcoGen G0070340 Specifications