Section 1 Brushless Capacitor Excitation
4 Diagnostic Repair Manual
Problem 2 – Voltage & Frequency Are Both High or Low
Problem 3 – Excessive Voltage/Frequency Droop When Load is Applied
Problem 4 – Generator Produces High Voltage at No-Load
TEST 30 – CHECK & ADJUST ENGINE
GOVERNOR, 410cc ENGINE
GO TO
PROBLEM 1
GO TO
PROBLEM 3
GO TO PROBLEM 1,
TEST 6 – CHECK
CAPACITOR
FREQUENCY GOOD, LOW OR
RESIDUAL VOLTAGE
FREQUENCY IS GOOD BUT
NO-LOAD VOLTAGE IS HIGH
NO-LOAD FREQUENCY & VOLTAGE GOOD BUT
THEY DROOP TO MUCH WHEN LOAD IS APPLIED
GO TO PROBLEM 23
REDUCE LOAD
END TEST
TEST 10 – CHECK
LOAD VOLTAGE &
FREQUENCY
TEST 11 – CHECK
LOAD WATTS &
AMPERAGE
GOOD
GOOD
BAD
OVERLOADED
NOT OVERLOADED
TEST 30 – CHECK
& ADJUST
ENGINE
GOVERNOR,
410cc ENGINE
STOP
TESTS
REPLACE
TEST 1 – CHECK
NO-LOAD VOLTAGE
AND FREQUENCY
FREQUENCY AND
VOLTAGE O.K.
FREQUENCY O.K.,
BUT VOLTAGE HIGH
FREQUENCY
HIGH
BAD
GO TO “PROBLEM 1”,
TEST 7 – TEST BRUSHLESS
DPE WINDING
FREQUENCY O.K., BUT
VOLTAGE IS STILL HIGH
TEST 6 –
CHECK
CAPACITOR
TEST 30 – CHECK & ADJUST ENGINE
GOVERNOR, 410cc ENGINE

Table of Contents

Other manuals for Generac Power Systems XT8000EFI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems XT8000EFI and is the answer not in the manual?

Generac Power Systems XT8000EFI Specifications

General IconGeneral
BrandGenerac Power Systems
ModelXT8000EFI
CategoryPortable Generator
LanguageEnglish

Related product manuals