Enable or disable selected general system options:
1. Faults auto-restore
enabled – fault indication is suppressed au-
tomatically when the fault is not longer
present (default),
disabled – fault indication requires manual
acknowledgment to suppress (EN50131).
2. Installer tamper restore
enabled – tamper indication may only be re-
stored by an installer (EN50131),
disabled – tamper indication may be re-
stored by user or installer (default).
3. Sounders on tamper if armed only
enabled – outdoor sirens signal tamper only
if system is armed (EN50131),
disabled – outdoor sirens signal tamper if
system is armed or disarmed (default).
4. User bypasses tamper
enabled – zone bypass in user menu by-
passes both violation and tamper signals,
disabled – zone bypass in user menu by-
passes only violation signals (default).
5. Installer lock
enabled – starting service mode using Ser-
vice jumper disabled,
disabled – starting service mode using Ser-
vice jumper enabled (default).
6. Alarm if zone open after exit
enabled – alarm from a zone violated at the