end of exit delay will be notified immedi-
ately
disabled alarm from a zone violated at the
end of exit delay will be notified when the
zone will be restored and violated again (de-
fault).
7. Tamper on 10 wrong codes
enabled after 10 attempts of entering
wrong code on the keypad, the keypad will
be locked for 60s and tamper signal will be
notified,
disabled after 10 attempts of entering
wrong code on the keypad, the keypad will
be locked for 60s without tamper signal be-
ing notified (default).
8. Check after exit delay
enabled if there will be any fault or zone
open after exit delay, the system will not
arm (EN50131),
disabled the system will arm after exit de-
lay regardless of any faults and/or open
zones (default).
139. RTC clock synchronization
Selects RTC synchronization mode:
1 Manual RTC set without automatic DST,
2 Manual RTC set with automatic DST,
3 Auto-set using GSM network time (default).
The availability of automatic GSM network time
synchronization depends on GSM operators' infra-