structure.
138. AC fault delay
Changes the AC fault detection delay in minutes.
Setting to 0 disables the delay.
Default: 5
8.6.3.2 Hardware
List of connected modules
Displayes the list of detected modules connected to
system bus.
The mark displayed by the module name indi-
cates that the module is registered in control panel.
Registering the module means it's presence is su-
pervised by the panel and the panel will respond
with tamper signal if the communication with the
module would be lost. Additionally, the panel will
store individual settings for registered devices.
Pressing the Details function key displays the
detailed information on currently selected module -
its UID-unique hardware identifier, and firmware
version.
124. Modules registration
Function performs automatic registration of cur-
rently detected modules. Once module will be reg-
istered in control panels' memory, it's presence will
be supervised by the panel and individual module
settings will be kept in panel's non-volatile mem-
ory.