211. Partition entry delay
Entry delay in seconds time between opening
delayed” type zone and starting alarm signaling.
Default: 30
221. Partition exit delay
Exit delay in seconds time of ignoring intruder
zones (except “Perimeter type zones) after initial-
izing of partition arming.
Default: 30
241. Partition options
Enables or disables partition options:
1 Quick arm Stay enabled
enabled – Stay mode Quick-arm enabled,
disabled – Stay mode Quick-arm disabled.
2 Quick arm Away enabled
enabled – Away mode Quick-arm enabled,
disabled – Away mode Quick-arm disabled.
3 Reserved
4 Reserved
5 Hold-down Panic discreet
enabled hold-down Panic alarm discreet
(notification/reporting only)
disabled hold-down Panic alarm with full
alarm
Default: 1, 2
8.6.3.4 Zones
Line (EOL) configuration
301...306. EOL for Z1...Z6 (PRiMA 6)