24 Service mode indicator
Indicates active service mode.
Default: OUT1: 2, OUT2: 1, PGM3...PGM6: 0
Outputs cut-off time
521...524. OUT1...PGM4 cut-off time (PRiMA6)
521...526. OUT1...PGM6 cut-off time (PRiMA12,16)
OUTx, PGMx outputs cut-off time, by default
specified in seconds. If a “Cut-off time in min-
utes” attribute is set for an output, then the
cut-off time is specified in minutes.
If the cut-off time is set to 0, the output is ac-
tive until manually canceled/restored.
Default: 45
Outputs attributes
541...544. OUT1...PGM4 (PRiMA6) attributes
541...546. OUT1...PGM6 (PRiMA12,16) attributes
Enable or disable OUTx, PGMx attributes, ac-
cording to the following table:
1 Polarity reversal
Reverses the output logical polarity:
disabled – high impedance when inac-
tive, short to COM when active,
enabled – short to COM when inactive,
high impedance when active.
2 Arm/disarm chirp
disabled – no arm/disarm chirp (bell
squawk) when arming/disarming using
arm/disarm zones,
disabled – generates arm/disarm chirp

Table of Contents