(bell squawk) when arming/disarming
using arm/disarm zones:
1 short chirp: arming,
2 short chirps: disarming,
4 short chirps: disarming with alarm re-
store.
3 Latch
disabled – output deactivates after pro-
grammed time,
enabled – output does not deactivate
after programmed time, remains active
until manually canceled.
4 Cut off time in minutes
disabled – cut-off time programmed in
functions 521...526 specified in seconds,
enabled – cut-off time programmed in
functions 521...526 specified in minutes,
5 Pulsating
disabled – output activation continuous,
disabled – output activation pulsates
with frequency of 1Hz,
6 Fire alarm as intruder
disabled – fire alarm pulsating (evacua-
tion mode), other alarms continuous,
disabled – all alarms continuous,
Default: -
Outputs activation delay
561...564. OUT1...PGM4 activation delay (PRiMA6)
561...566. OUT1...PGM6 activation delay (PRi-