4.1 Information texts
The information texts appear on the display in plain text.
Note!
Indicates at the start of a process that a dosing detergent
has run out (Low level Det 1-4) means the machine cannot
be started before the detergent has been added.
Note!
When the information text (which appears in the display) is
activated , there is always detergent remaining for one
cycle, that is, the program that was started can finish
running.
The following information texts can be shown on the display:
Information text Description
STARTING Displayed during a process. Indicates the current status of the process.
DISINFECTION Displayed during a process. Indicates the current status of the process.
DRAINING Displayed during a process. Indicates the current status of the process.
ALARM DRAIN Displayed during a process. Indicates the current status of the process.
SELECT PROGRAM
Displayed during a process. Indicates the current status of the process.
DET 1 LOW LEVEL Empty container alarm 1. If detergent 1 is finished, information text is
generated. The indicator is reset automatically when detergent is added.
DET 2 LOW LEVEL Empty container alarm 2. If detergent 2 is finished, information text is
generated. The indicator is reset automatically when detergent is added.
DET 3 LOW LEVEL Empty container alarm 3. If detergent 3 is finished, information text is
generated. The indicator is reset automatically when detergent is added.
DET 4 LOW LEVEL Empty container alarm 4. If detergent 4 is finished, information text is
generated. The indicator is reset automatically when detergent is added.
DOOR OPEN Start conditions. The door is not closed.
MANUAL MODE SET Start conditions. A digital output port is set to manual operation. Reset output
(possible via panel).
SELECT PROGRAM Start conditions. An invalid program has been selected. Select another
program (P1-P16).
EXT COM. NOT
OK (option)
Start conditions. No communication between PACS and the NetCOM card.
Wait 60 seconds and try again. If the error remains: Check the cabling and
settings.
SERVICE ALARM Indicates that a preventative service has to be carried out according to the
service schedule.
4 ALARM MANAGEMENT
TECHNICAL MANUAL GETINGE WD15 CLARO 51 (128)
<Doc_TEC><Doc_6001396902><Rev.I><Lang_en>