Instruction manual Technical specifications
7
6 Technical specifications
Resolution of time calculation
Dynamics (turn-down ratio)
0.1m/s - 10m/s (0.3 ft/s - 32 ft/s)
High purity water, clean water with < 3 percent by volume
of particle content, or up to 30% ethylene glycol.
± 3 % of flow value with a flow rate of > 0.3 m/s
± 0.15 % of measured value
Selectable units of
measurement
l/s, l/min, m
3
/min, m
3
/hr
gal/s, gal/min, USgal/s, USgal/min
Opto-isolated MOSFET volt free contact (NO/NC)
Up to 166 pulses/s (depending on pulse width)
200 Hz max. (Range 1-200)
Max. voltage/current load
1500 V optically insulated