14
Run the connection cable through the housing
and insert the plugs.
Tighten the cable gland.
Damage due to moisture or penetrating foreign bodies
Check that all cable glands are tight.
Seal open and unused cable entries with blanking plugs. This will prevent moisture or foreign bodies
such as insects from penetrating.
7
Connecting external devices
Danger to life from electric shock!
Improper wiring may result in severe or fatal injury from electrical current.
Allow only qualified electricians to carry out the work.
Disconnect all cables from the power supply.
Secure the mains disconnector against plugging in or switching it on again.
Observe valid regulations and standards.
Use suitable tools.
Check the insulation of cables and make sure that cables outdoors are protected.
i
The inputs of the following safety devices of the control are rated Performance Level c (PLc):
Slack-rope switch
Pass-door switch
Safety edge
Limit switch system
Safety circuit of the drive unit
i
Connect only sensors that comply with the current EN 12453 and are suitable for