4 Product overview
Technical data
D
esignation
Expression
Dimensions
(B x H x T)
155 x 386 x 90
Weight
2 kg
Operating frequency
50 Hz / 60 Hz
Supply voltage
1 N~220
-
230 V, PE
3 N~220-400 V, PE
3~220
-
400 V, PE
Output power for drive unit, maximum
3 kW
Temperature
range
Operation
Storing
-
10 °C
-
+50 °C
0 °C
-
+50 °C
Air humidity, non
-
condensing
max. 93 %
Power consumption door control
4
W
Protection class
Housing
IP65
with
CEE
connection kit
See the IP protection class of the connection kit
Protection per phase, on
-
site
10 A
-
16 A
External mains supply:
X1.8 / X1.9
Protection via F1 micro-fuse
1 N~230 V
1,6 A time-lag
Relay contact
1
potential
-
free changeover contact
Loading of relay contacts
ohm
ic
230 V AC, 1 A
24 V DC, 0,4 A
indu
ctive
Control inputs
24 V DC, typ. 10 mA
Compatible GfA
-
limit switch
Mechanical limit switch
(NES)
Digital limit switch
(DES)

Table of Contents