25
P 9.5 - Reset to factory settings / use of GfA-Stick
Activate the GfA-Stick with option .0 The GfA-Stick (part no. 20003696) allows readout of faults, operations,
and programming by using the GfA App. With option . 1, you delete all set menu items and reset the door
control to factory setting.
9.5
Reset to factory settings / use of GfA-Stick
.0
Activate GfA-Stick.
.1
Reset to factory settings.
Press the OPEN Button once to select menu item . 1.
Confirm your selection by pressing the STOP Button for 3 seconds.
10
Fault correction
i
NOTE
You can find detailed information on faults and how to rectify them in our
fault guide for door controls.
Download the fault guide from the GfA-Portal.
Start the fault guide using the GfA+ app.
Fault indications
Door control is off / display is dark
Possible causes Fault correction
Display is
dark /
door
control is
without
function
No input function
Measure the input voltage.
Overload
Check whether too many electrical loads are connected to the
control circuit (24 V).
Short circuit
Check whether a faulty device is connected to the control
circuit (24 V).
Water damage Check if water has entered the control box.
A different defect
Disconnect all lines (delivery status).
Replace the door control if the display stays dark.
Fault in the safety circuit
Cause of the fault Fault correction