General IconGeneral
BrandGFA
ModelTS 970
CategoryControl Unit
LanguageEnglish

Summary

General Safety Information

Safety Information

Emphasizes that installation and commissioning should only be done by skilled and trained personnel.

Mechanical Installation

Control Installation Guidelines

Crucial instructions for installing the control unit indoors, on stable surfaces, and in a vertical position.

Mounting Procedure

Illustrates the physical mounting process using elongated holes for secure attachment.

Electrical Installation

Electrical Safety Warnings

Highlights critical electrical safety warnings, including disconnecting power and using proper tools.

Backup Fuse and Disconnector Unit

Provides specific guidance on the type of fuses and disconnectors required for on-site installation.

Carrying Out Electrical Installation

Electrical Installation Steps

Guides through removing covers, opening entries, connecting cables, and tightening glands securely.

Damage Prevention

Warns against damaging components during installation and recommends using suitable tools.

Mains Supply and Connection

Mains Supply Options

Details different mains supply configurations (3-phase, single-phase) and their terminal connections.

Mains Connection Procedure

Illustrates the process of connecting the mains power supply to the control unit.

Starting Up the Control

DES: Rapid Limit Position Adjustment

Guides setting final limit positions for DES, covering rotation check, OPEN/CLOSE movement, and saving positions.

NES: Rapid Limit Position Adjustment

NES Limit Position Setup

Guides setting final limit positions for NES, including rotation check and specific limit switch configurations.

Electrical Installation - Control Accessories

External Supply and Emergency Stop

Details wiring for external power supply and the connection of emergency stop devices.

Automatic Closing and Control Device Connections

Explains connections for automatic closing switches and general external control devices.

Electrical Installation - Accessory Connections

Light Curtain, Receiver, and Pull Switch Connections

Details wiring for light curtains, radio receivers, and pull switches.

Control Programming Guide

Programming Steps

Guides through starting, selecting menu items, setting functions/positions, and exiting the programming mode.

Table Menu Items

Door Operating Modes Configuration

Describes and allows configuration of different operating modes for the door.

Door Positions

DES Final Limit Position Setup

Guides setting coarse and fine OPEN/CLOSE final limit positions for DES systems.

DES Safety Edge Pre-limit Setup

Details fine-tuning the pre-limit switch for safety edges in DES systems.

Door Functions - Part 4

Safety Functions Overview

Details force monitoring, photo cell interruption, travel time monitoring, door safety switches, and reversing duration adjustments.

Safety Devices - Door Switches

Door Safety Switch Functionality

Details the functions, reactions, and types (NC/NO) of door safety switches.

Safety Devices - Safety Edge Systems

Safety Edge System Overview

Explains the automatic detection of different safety edges and important connection notes.

Emergency Operation and Stop

Emergency Operation Procedure

Guides the user on how to activate and safely use the emergency operation mode.

Emergency Stop Input (X3)

Details the connection and function of the emergency stop input, including specific notes for frequency inverter drives.

Functional Description - Power Supply

Mains Supply Connections

Details mains supply connections for the control unit and external devices, including voltage options and protection.

Functional Description - Photo Cells and Light Curtains

Relay Contact and Force Monitoring

Force Monitoring (DES Only)

Details the force monitoring system for DES, its purpose, limitations, and important considerations.

Travel Time Monitoring (NES)

Travel Time Monitoring (NES Only)

Explains the travel time monitoring feature for NES, including fault indications and reset procedures.

Status Display and Faults

Fault Code Overview

Lists fault codes, descriptions, causes, and corrections for various operational issues encountered by the control.