10
Refrigerant
Refrigerant quantity
g
1600
1800
Refrigerant
R32
R32
Pipe length without additional
charge
m
5
5
Refrigerant charge(Pipe
length>5m)
forφ6.35Pipe length-5*15g/m
forφ9.52Pipe length-5*20g/m
NotePiping length means that liquid side
of each indoor unit.
Piping data
Liquid side/Gas side
mm
3×(6.35/9.52)
3×(6.35/9.52)
Max. pipe lengthtotal
m
45
45
Max. height difference between indoor unit and
outdoor unit( ODU below)
m
10
10
Max. height difference between indoor unit and
outdoor unit( ODU above)
m
10
10
Max. height difference between indoor unit and
indoor unit
m
5
5
Main power of outdoor unit cable
3*4mm²
3*4mm²
Connecting wire of indoor unit and outdoor unit
4*1mm²
4*1mm²
Ambient
temperature
Cooling
-15~52
-15~52
Heating
-15~34
-15~34
Application area
m
2
3*10~15
3*12~18