Running mode (0: shutdown, 1: cooling,
3: heating, 4: forced cooling)
T1 room temperature of indoor unit B
Indoor unit demanded capacity
EXV opening degree of indoor unit B
Indoor unit C demanded capacity
T1 room temperature of indoor unit C
EXV opening degree of indoor unit C
Average evaporator temperature
Indoor unit D demanded capacity
T1 room temperature of indoor unit D
T4 outdoor ambient temperature
EXV opening degree of indoor unit D
Indoor unit E demanded capacity
T1 room temperature of indoor unit E
EXV opening degree of indoor unit E
Average temperature of T2B
Frequency limit (1: current limit, 2:
cooling limit, 4: T5, 8: T3, 16: T2)
The quantity of indoor units
The reason of T6 protection
The quantity of turned on indoor units
Indoor unit A demanded capacity
T1 room temperature of indoor unit A
Last error or protection code
EXV opening degree of indoor unit A
3. Indoor unit errors troubleshooting
Communication
error between
ODU & IDU
1. communication wires connect wrongly
2. fire and zero line of IDU and ODU should be one-to-one
corresponding
3. There is interference in the lines or damage to the indoor and outdoor
PCBs.
1. Check whether the sensor connector is loose, if the plug is loose,
reconnect the plug, otherwise proceed to the next inspection;