14
2.3 Cassette unit
Cassette IDU
CCB-
D07HR4-
Q402
CCB-
D09HR4-
Q402
CCB-
D12HR4-
Q402
CCB-
D18HR4-
Q402
Power supply
V/ph/
Hz
220~240/1/50
220~240/1/50
220~240/1/50
220~240/1/50
Coolin
g
Capacity
Btu/h
7000
9000
12000
18000
kW
2.1
2.6
3.5
5.3
Input
W
25
25
26
34
Rated current
A
0.12
0.12
0.12
0.16
Heatin
g
Capacity
Btu/h
8000
10000
13000
19000
kW
2.3
2.9
3.8
5.6
Input
W
25
25
26
34
Rated current
A
0.12
0.12
0.12
0.16
Fan
motor
Model
DR-310-35Q-
8-1
DR-310-35Q-
8-1
DR-310-35Q-
8-1
DR-310-35Q-
8-1
Type
DC
DC
DC
DC
Input
W
21/16/12
21/16/12
23/18/13
30/24/18
Speed(H/M/L)
r/min
540/490/410
540/490/410
690/610/520
790/740/610
Indoor
coil
Number of rows
2
2
2
2
Tube pitch(a) ×row
pitch(b)
mm
21*13.37
21*13.37
21*13.37
21*13.37
Fin type
Hydrophilic
Hydrophilic
Hydrophilic
Hydrophilic
Fin spacing
mm
1.4
1.4
1.4
1.4
Tube outside dia.
and type
mm
7
7
7
7
Inner screw
Inner screw
Inner screw
Inner screw
Coil size (W*D*H)
mm
1313*26.74*2
10
1313*26.74*2
10
1313*26.74*2
10
1313*26.74*2
10
Number of circuits
4
4
4
4
Indoor air flow(Hi/Mi/Lo)
m
3
/h
540/490/410
540/490/410
690/610/520
790/710/610
Indoor noise(Hi/Mi/Lo)
dB(A
)
39/36/33
39/36/33
40/37/34
44/41/38
Sound power noise level
Hi
dB(A
)
50
50
54
55
Net dimension(W×H×D)
mm
580×267×580
580×267×580
580×267×580
580×267×580
packing dimension(W×H×D)
mm
755×375×680
755×375×680
755×375×680
755×375×680
Net/Gross weight
kg
16.5/21.5
16.5/21.5
16.5/21.5
16.5/21.5
Liquid/Gas
mm
6.35/9.52
6.35/9.52
6.35/9.52
6.35/12.7
Drainage pipe
mm
DN25
DN25
DN25
DN25
Application area
m
2
10~15
12~18
16~23
23~34
Dehumidification
kg/h
0.5
0.6
0.84
1.27