44
2. Selecting installation place
Indoor unit
Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles in front or around the unit.
Make sure that condensation drainage can be conveniently routed away.
Do not install near a doorway.
Ensure that the space on the left and right of the unit is more than 15cm.
Use a stud finder to locate studs to prevent unnecessary damage to the wall.
The indoor unit should be installed on the wall at a height of 2.0 meters or
more from the floor.
The indoor unit should be installed allowing a minimum clearance of 15cm from the
ceiling.
Any variations in pipe length will/may require adjustment to refrigerant charge.
There should not be any direct sunlight. Otherwise, the sun will fade the
plastic cabinet and affect its appearance. If unavoidable, sunlight prevention
should be taken into consideration.
Outdoor unit
If an awning is built over the outdoor unit to prevent direct sunlight or rain
exposure, make sure that heat radiation from the condenser is not restricted.
Ensure that the clearance around the back of the unit is more than 30cm and left
side is more than 30cm. The front of the unit should have more than 200cm of
clearance and the connection side (right side) should have more than 60cm of
clearance.
Do not place animals and plants in the path of the air inlet or outlet.
Take the air conditioner weight into account and select a place where noise and
vibration will not be an issue.
Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.