71
P1x
Bus voltage protection
P21
Low temperature dehumidification fault
P22
High and low temp. protection of evaporator
P23
High temp. protection of condenser
P24
High and low temp. protection of environment
P25
High discharge temperature of compressor
P28
Abnormal discharge in commodity inspection mode (compressor reversal)
P29
T3 abnormal in commodity inspection heating mode (System exception, 4-way valve
disconnected)
P30
High pressure protection
P31
Low pressure protection
H1x
Compressor fault
H3x
PFC fault
L01
Lower frequency because of voltage limit
L02
Lower frequency because of high or low temp. limit of evaporator
L03
Lower frequency because of high temp. limit of condenser
L05
Lower frequency because of high discharge temp. of compressor
L06
Lower frequency because of IPM temperature limit
L0C
Lower frequency because of current limit
1.3 One drive three/four/five outdoor unit
Error code
Description
E2
Communication error between IDU and ODU
E4
Environment temperature (T4) sensor fault
E5
Discharge temperature sensor fault
E6
Condenser temperature sensor fault
E9
AC overcurrent/undercurrent protection
E10
EEPROM error
H0
Communication error between main chip and DSP