56
7.2.1 Lay out installation points
1) Drill holes for both wall hooks and insert anchors (field supplied). Secure unit mounting hooks to
the wall.
It is recommended to install screw anchors for sheet rock concrete block, brick and such type of
walls.
2) Verify the location
Lift and set the console on the 2 wall hooks. The wall hooks should catch metal mounting
bracket on the rear of the console.
Verify the unit mount holes align with wall holes.
Verify refrigerant piping and condensate drain pipe locations are valid for the unit.
Verify unit is level right to left.
3) Remove indoor unit from anchor bolts in order to begin making piping connections.
7.2.2 Drill holes in wall
1) Carefully remove indoor unit from wall mounting hooks.
2) Cut the wall hole with a 5° to 10° downward slant to the outdoors.
3). Insert a wall sleeve (factory supplied) into hole to prevent damage to refrigerant pipes, insulation,
condensate drain pipe and wiring.
4). Proper weather proofing of the wall surface and wall sleeve is essential to assure a trouble-free
installation. Apply sealant, caulking or equivalent weather proofing material around the perimeter of
the wall sleeve (interior & exterior) to eliminate outdoor air and water leaks into the indoor space.