EasyManuals Logo

Goodwe HT Series User Manual

Goodwe HT Series
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
28
06 Electrical Connection
User Manual V1.1-2022-07-20
NOTICE
Make sure that the cables are connected correctly and rmly after connections. Clean all the
debris in the maintenance compartment.
Seal the AC output terminal to ensure the Ingress Protection Rating.
6.5 Communication
6.5.1 Connecting the Communication Cable
NOTICE
Make sure that the communication device is connected to the right COM port. Route the
communication cable far away from any interference source or power cable to prevent the
signal from being inuenced.
RS485+
Ethernet
RS485-
L1
L2
L3
N
PE
CT
CT
CT
......
Three-phase
circuit breaker
Inverter 1Inverter N
SEC1000
Router
Meter
Grid
Cloud
Power limit networking scenario
After completing cable connections, set related parameters via LCD or SolarGo app to enable
export power limit control or output power limit control.
M8
7~9N·m
3
M5
2.5~3N·m
1
L2
PE
2
2
2
2
3
L1
N
L3
M12
25~30N·m
2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe HT Series and is the answer not in the manual?

Goodwe HT Series Specifications

General IconGeneral
Max DC Input Voltage1100V
MPPT Voltage Range200-1000V
Max AC Output Power3.6kW to 10kW
Number of MPPTs1 or 2
Max PV Input Voltage1100V
MPPT Range200-1000V
AC Output Frequency50/60Hz
CommunicationRS485, Ethernet
Operating Temperature Range-25°C to 60°C
Protection LevelIP65