46
09 Maintenance
User Manual V1.1-2022-07-20
No. Fault Cause Solutions
35 Model Error
1. Temporary
abnormality
is caused by
environmental
factors.
2. Internal
components of
the inverter are
damaged.
Disconnect the AC output switch and DC input
switch, then connect them 5 minutes later.
Contact the dealer or the after-sales service if the
problem persists.
36
Pv Short
Failure
The hardware is
abnormal.
Please contact your dealer or after-sale service.
37
BUS-start
Fail
1. The output
power of the PV
string is too low.
2. The control
circuit is
abnormal.
Disconnect the AC output switch and DC input
switch, then connect them 5 minutes later.
Contact the dealer or the after-sales service if the
problem persists.
38
PV Over
Voltage
Excess PV modules
are connected in
the series, and the
open-circuit voltage
is higher than the
operating voltage.
1. Check whether the PV string input voltage
consistent with the value displayed on the
LCD.
2. Check whether the PV string voltage meets the
maximum input voltage requirements.
39
PV Voltage
Low
Sun light is weak
or changing
abnormally.
1. If the problem occurs occasionally, the reason
might be abnormal sun light. The inverter
will recover automatically without manual
intervention.
2. If the problem occurs frequently, contact the
dealer or the after-sales service.
40 PV HCT Fail
1. Temporary
abnormality
is caused by
environmental
factors.
2. Internal
components of
the inverter are
damaged.
Disconnect the AC output switch and DC input
switch, then connect them 5 minutes later.
Contact the dealer or the after-sales service if the
problem persists.
41 PV over Curr
Disconnect the AC output switch and DC input
switch, then connect them 5 minutes later.
Contact the dealer or the after-sales service if the
problem persists.
42
Bus
Unbalance
1. The sampling
circuit of
the relay is
abnormal.
2. Abnormal
hardwares
Disconnect the AC output switch and DC input
switch, then connect them 5 minutes later.
Contact the dealer or the after-sales service if the
problem persists.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe HT Series and is the answer not in the manual?

Goodwe HT Series Specifications

General IconGeneral
Max DC Input Voltage1100V
MPPT Voltage Range200-1000V
Max AC Output Power3.6kW to 10kW
Number of MPPTs1 or 2
Max PV Input Voltage1100V
MPPT Range200-1000V
AC Output Frequency50/60Hz
CommunicationRS485, Ethernet
Operating Temperature Range-25°C to 60°C
Protection LevelIP65