Adjust Abrasive Media
1. Perform the Adjust Blast Pressure procedure on
page 18.
2. Open the abrasive media ball valve (J). Trigger the
blast control switch (A).
3. Turn on the MediaTrak display (PK).
4. Slowly adjust the abrasive meter valve (P) to the
desired flow of abrasive media.
NOTE: You may have to wait 1-2 minutes for the
abrasive material to reach the nozzle.
NOTE: Use a piece of test material similar to what you
will be blasting. Always start as gently as possible and
then increase the blast force as necessary to clean
without doing any damage to the substrate.
WLD
-
8800000
ti36971b
A
PK
P