8. Place a bucket under the abrasive hose. Slowly
open the abrasive ball valve to flush abrasive mate-
rial from the pot.
NOTE: Once the water surges from the abrasive
hose, close the ball valve and pull up on the pop-up
handle once water is above the pop-up seal to
re-pressurized the pot. Repeat until all abrasive has
been emptied from the pot.
9. Close the fill/flush valve.
10. Open the abrasive ball valve and drain the pot of
water.
11. Connect the abrasive hose.
NOTE: The system must be winterized if it will be
exposed to temperatures below freezing
(see Winterizing the Equipment, page 21).