Operation
3A4802D 9
Connecting the Water Supply
Pressurized water supply
1. Close the fill/flush valve (XD).
2. Connect to a pressurized water supply hose with a
minimum ID of 3/4 in. (19 mm) to the garden hose
connection (XG).
A
NOTE: The maximum water supply pressure is 100
psi (6.8 bar, 0.68 MPa). The minimum flow require-
ments is 1 gpm (3.8 lpm).
3. Turn on water supply.
Non-Pressurized Water Supply
NOTE: The fill/flush valve will not operate with a
non-pressurized water supply.
NOTE: To prime the pump, turn the selector valve to
BLAST.
Using a Siphon Hose
1. Close the fill/flush valve (XD).
2. Disconnect the pump inlet hose at the pump inlet.
3. Connect the included siphon hose to the pump inlet
to draw from a 5 gallon bucket or an open container.
Using the Water Tank Kit
1. Disconnect the pump inlet hose at the pump inlet.
2. Connect the pump inlet adapter fitting included in
the water tank kit (see Kits and Accessories on
page 39) to the pump inlet and follow the kit
instructions.
NOTICE
Pump runaway can damage pump seals. If the pump
begins to run too fast, shut it down to avoid damage.