Operation
Husky™ Husky™
Husky™
2200 2200
2200
Air Air
Air
- -
-
Operated Operated
Operated
Diaphragm Diaphragm
Diaphragm
Pump Pump
Pump
3A2578E
EN
Polypropylene Polypropylene
Polypropylene
and and
and
PVDF PVDF
PVDF
pumps pumps
pumps
for for
for
󰘱uid 󰘱uid
󰘱uid
transfer transfer
transfer
applications, applications,
applications,
including including
including
high high
high
viscosity viscosity
viscosity
materials. materials.
materials.
For For
For
professional professional
professional
use use
use
only. only.
only.
Not Not
Not
for for
for
use use
use
in in
in
European European
European
explosive explosive
explosive
atmosphere atmosphere
atmosphere
locations. locations.
locations.
Important Important
Important
Safety Safety
Safety
Instructions Instructions
Instructions
Readallwarningsandinstructionsinthismanualandinyour
Repair/Partsmanual.Save Save
Save
these these
these
instructions. instructions.
instructions.
Maximum Working Pressure: 125 psi
(0.86 MPa, 8.6 bar)
PROVENQUALITY.LEADINGTECHNOLOGY.
www.northridgepumps.com

Other manuals for Graco Husky 2200

Questions and Answers

  • D
    davidhillAug 21, 2025
    How to fix a Graco Water Pump that cycles but won't prime?
    • M
      Michael WilliamsAug 21, 2025
      If your Graco Water Pump cycles but won't prime, first try reducing the air inlet pressure, as the pump might be running too fast, causing cavitation. Also, inspect the check valve ball for wear or obstructions and replace the ball and seat if necessary. Check the seat for wear and replace the ball and seat. Ensure that the outlet and inlet are not clogged; unclog them if necessary. Make sure the inlet and outlet valves are open, and tighten any loose inlet fittings or manifolds. Replace any damaged manifold o-rings.
  • M
    Mr. Peter GoodwinSep 4, 2025
    Why does my Graco Husky 2200 Water Pump cycle at stall but fails to hold pressure?
    • T
      Travis HermanSep 4, 2025
      If your Graco Water Pump cycles at stall but fails to hold pressure, it's likely due to worn check valve balls, seats, or o-rings, which will need to be replaced.
  • M
    Mrs. Julie WestSep 3, 2025
    Why does my Graco Water Pump exhaust excessive air at stall?
    • J
      John Branch MDSep 3, 2025
      If your Graco Water Pump exhausts excessive air at stall, the air valve cup or plate may be worn and needs replacement. Other potential causes include a damaged air valve gasket or damaged pilot valve, both of which should be replaced. Also, worn shaft seals or bearings can cause this issue, so replace them if necessary.
  • J
    Jessica VegaSep 1, 2025
    Why does my Graco Water Pump exhaust air contain fluid?
    • L
      Linda DiazSep 1, 2025
      If the exhaust air of your Graco Water Pump contains fluid, the diaphragm is likely ruptured and needs to be replaced. Another possible cause is a loose diaphragm shaft bolt, which should be tightened or replaced.
  • L
    Leah WilliamsAug 30, 2025
    How to fix a Graco Water Pump that won't cycle?
    • C
      christophercummingsAug 30, 2025
      If your Graco Water Pump won't cycle, or cycles once and stops, the air valve might be stuck or dirty; disassemble and clean it, ensuring you use filtered air. Another potential cause is a severely worn check valve ball wedged in the seat or manifold, in which case you should replace the ball and seat. A worn, damaged, or plugged pilot valve could also be the issue, so replace the pilot valve. Check for a damaged air valve gasket and replace it if necessary. Finally, a clogged dispensing valve could be the cause; relieve the pressure and clear the valve.
  • K
    Karl DavisAug 29, 2025
    What to do if my Graco Husky 2200 Water Pump leaks fluid externally from joints?
    • M
      Mary RiveraAug 29, 2025
      If your Graco Water Pump is leaking fluid externally from joints, it's likely due to loose manifold screws or fluid cover screws; tighten them. Another possibility is worn-out manifold o-rings, which should be replaced.
  • C
    Christine SmithAug 28, 2025
    What to do if my Graco Husky 2200 operates erratically?
    • L
      laurawhitneyAug 28, 2025
      If your Graco Water Pump is operating erratically, several issues could be the cause. Start by inspecting the suction line for clogs and clear them. Check the check valve balls for stickiness or leaks, and clean or replace them if necessary. A ruptured diaphragm could also be the problem, so replace it. Ensure there is no restricted exhaust by removing any restrictions. Damaged or worn pilot valves or air valve can cause this issue, so replace them if needed. Also, check the air valve gasket for damage and replace it if necessary. An erratic air supply can cause this issue, so repair the air supply. Finally, exhaust muffler icing can lead to erratic operation, so use a drier air supply.
  • M
    Mark ThompsonAug 26, 2025
    Why does my Graco Husky 2200 cycle but not prime?
    • M
      Molly DiazAug 27, 2025
      Several factors can cause a Graco Water Pump to cycle without priming. The pump might be running too fast, leading to cavitation; reduce the air inlet pressure to resolve this. Inspect the check valve ball for wear or if it's wedged, and replace the ball and seat if necessary. Also, a worn seat can cause this issue, so replace the ball and seat. Check for clogs in the outlet or inlet and unclog them. Ensure the inlet or outlet valve is open, and tighten any loose inlet fittings or manifolds. Lastly, inspect manifold o-rings for damage and replace them if needed.
  • W
    William JohnsonAug 25, 2025
    What to do if my Graco Husky 2200 has air bubbles in the fluid?
    • J
      Jason RuizAug 26, 2025
      If you notice air bubbles in the fluid, several issues could be the cause. First, check if the suction line is loose and tighten it. A ruptured diaphragm could also be the culprit, so consider replacing it. Inspect manifolds, seats, and o-rings for looseness or damage; tighten manifold bolts or replace seats or o-rings as needed. Pump cavitation might be happening, so reduce the pump speed or suction lift. Finally, ensure the diaphragm shaft bolt is tightened.
  • R
    Ross CampbellAug 23, 2025
    How to fix Graco Husky 2200 leaking air externally?
    • M
      megan21Aug 23, 2025
      If your Graco Water Pump is leaking air externally, ensure that the air valve or fluid cover screws are tightened. If the diaphragm is damaged, replace it. Also, replace the air valve gasket if it is damaged.

Summary

Warnings and Safety Precautions

Fire and Explosion Hazards

Hazards from flammable fumes and static charge in work areas.

Pressurized Equipment Hazards

Risks of fluid splashing from leaks or ruptured components.

Equipment Misuse Hazards

Dangers of operating the unit incorrectly or under influence.

Thermal Expansion Hazards

Risks of rapid pressure rise due to heat in confined spaces.

Plastic Parts Cleaning Solvent Hazards

Danger of solvents degrading plastic parts, causing failure.

Toxic Fluid or Fumes Hazards

Risks from toxic fluids or fumes causing injury or death.

Burn Hazards

Danger of burns from hot equipment surfaces and fluid during operation.

Personal Protective Equipment (PPE)

Importance of wearing appropriate PPE to prevent injury.

Ordering Information

Find Nearest Distributor

How to locate the nearest authorized Graco distributor for assistance.

Specify Pump Configuration

Guidance on selecting and configuring a new pump model.

Order Replacement Parts

Instructions on how to order necessary replacement parts for the pump.

Related Manuals

Information on other relevant manuals for the pump system.

Configuration Number Matrix

Understand Pump Configuration Numbers

How to use the matrix to define pump components based on configuration.

Installation Procedures

General Installation Guidelines

General guidance for selecting and installing system components.

Fastener Tightening Procedure

Procedure for checking and retorquing external fasteners before and after use.

Reduce Cavitation Tips

Methods to minimize cavitation for improved pump performance and longevity.

Pump Mounting Instructions

Guidelines for securely and accessibly mounting the pump.

Grounding the System

Critical steps for grounding the entire fluid system to prevent static sparking.

Air Line Connections

Instructions for installing air filter/regulator, master air valves, and air hose.

Air Exhaust Ventilation

Procedures for venting pump exhaust safely, especially for toxic fluids.

Fluid Supply Line Setup

Guidance on connecting the grounded, flexible fluid supply hose.

Fluid Outlet Line Setup

Steps for installing a fluid drain valve and a shutoff valve in the outlet line.

Flange Connections Procedure

Detailed procedure for connecting 2 in. (50 mm) plastic pipe flanges to the pump.

Operation and Startup

Pressure Relief Procedure

Steps to safely relieve system pressure before servicing or cleaning.

Pre-Use Pump Flushing

Instructions for flushing the pump to remove test water before initial operation.

Pump Startup and Adjustment

Guide to properly grounding, connecting, and starting the pump.

Pump Shutdown Procedure

Procedure for safely shutting down the pump at the end of a work shift.

Maintenance Guidelines

Maintenance Schedule Recommendations

Importance of establishing a preventive maintenance schedule for optimal performance.

Lubrication Requirements

Information on pump lubrication requirements (factory lubricated, no inline lubricator needed).

Threaded Connection Tightening

Regular checks and retorquing of fasteners and threaded connections.

Flushing and Storage Guidelines

Procedures for flushing and storing the pump to prevent damage.

Torque Instructions

Manifold Screw Torque Specs

Torque specifications and procedure for manifold fasteners.

Air Valve and Pilot Valve Torque

Torque specifications for air valve and pilot valve fasteners.

Fluid Cover Screw Torque

Torque specifications and procedure for fluid cover fasteners.

Pump Dimensions

End Flange Model Dimensions

Dimensional data for End Flange models in Polypropylene and PVDF.

Center Flange Model Dimensions

Dimensional data for Center Flange models in Polypropylene.

Performance Charts

Bolt-through Diaphragm Performance

Performance data for pumps with bolt-through diaphragms.

How to Read Performance Charts

Instructions on interpreting fluid pressure and air consumption curves.

Overmolded Diaphragm Performance

Performance data for pumps with overmolded diaphragms.

Technical Data

Pump Specifications Overview

Key technical specifications including pressure, size, and lift capabilities.

Air Consumption Data

Data on air consumption for different diaphragm types and pressures.

Noise Level Specifications

Information on sound power and sound pressure levels.

Fluid Flow per Cycle Data

Data on fluid volume delivered per pump cycle.

Maximum Free-Flow Delivery

Maximum flow rate achievable by the pump.

Pump Speed and Weight Data

Maximum pump speed ratings and pump weights for different materials.

Wetted and Non-wetted Parts Materials

Materials used for wetted and non-wetted components of the pump.

Fluid Temperature Range Limits

Operating temperature limits for various diaphragm/ball/seat materials.

Graco Standard Husky Pump Warranty

Warranty Terms and Exclusions

Details of the warranty coverage, exclusions, and limitations.

Graco Product Information and Support

Contact and website information for Graco products and support.

Graco Husky 2200 Specifications

General IconGeneral
Maximum Fluid Pressure120 psi (8.4 bar)
Maximum Suction Lift30 ft (9.1 m) wet
Maximum Solid Size1/4 in (6.3 mm)
Wetted PartsPolypropylene, Stainless Steel
Max Flow Rate2200 L/min (581 GPM)
Power SourceAir Operated
TypeAir-operated double diaphragm pump
Fluid Inlet Size2 in npt(f)
Fluid Outlet Size2 in npt(f)