EasyManuals Logo

Graco Magnum Pro Plus A30 Operation Instructions

Graco Magnum Pro Plus A30
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
Grounding Instructions
6 3A1177B
Grounding Instructions
Sprayer must be grounded. Grounding reduces the risk
of static and electric shock by providing an escape wire
for electrical current due to static build up or in the event
of a short circuit.
1. This sprayer requires 220-240 VAC, 50/60 Hz 10A
circuit with a grounding receptacle. Never use an
outlet that is not grounded.
2. Do not use sprayer if electrical cord has damaged
ground prong.
3. Do not use an extension cord with damaged ground
plug.
Recommended extension cords:
•15 m (49.2 ft) 1.0 mm
2
•30 m (98.4 ft) 1.5 mm
2
•50 m (164.0 ft) 2.5 mm
2
4. Smaller gauge or longer extension cords may
reduce sprayer performance.
Thermal Overload
Motor has a thermal overload switch to shut itself down
if overheated. If unit overheats, allow approximately 45
minutes for unit to cool. Once cool, switch will close and
unit will restart.
ti7529b
ti7528a
To reduce risk of injury from motor starting unexpect-
edly when it cools, always turn power switch OFF if
motor shuts down.

Other manuals for Graco Magnum Pro Plus A30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Magnum Pro Plus A30 and is the answer not in the manual?

Graco Magnum Pro Plus A30 Specifications

General IconGeneral
BrandGraco
ModelMagnum Pro Plus A30
CategoryPaint Sprayer
LanguageEnglish

Related product manuals