Installation
Fluid Fluid
Fluid
Connections Connections
Connections
Note: Note:
Note:
ProControl1KEPlusmodel25B289isfor
applicatorgunatomizingaircontrolonlyandwillhave
nouidinletoroutletconnections.
Fluid Fluid
Fluid
Inlet Inlet
Inlet
Connections Connections
Connections
Formodelsthatcomeequippedwiththestandard
G3000FluidMeter,connectincominguidto
theprovidedmetercheckvalvetting1/4npt(m)
inletport.Refertoinstructionmanual308778for
additionaldetailsregardinginstallationandoperation
oftheG3000meter.
Note
Usersareresponsibleforprovidingauid
inletshut-offvalveorothermeansofisolating
theuidsupply.
SeeAlternateFlowMeterandFluidRegulator
Installation,page26.Usersmustprovideuidttings
andhosewhenusingalternateFlowMetersorFluid
Regulators.
Fluid Fluid
Fluid
Outlet Outlet
Outlet
Connections Connections
Connections
TheProControl1KEPlusuidoutletconnectionwill
bemadeattheFluidPressureTransducerport1/4
npt(f)formostmodels.ForFlowMonitormodels
(25B285–25B288),theuidoutletconnectionwillbe
madeattheuidregulatoroutlet.
Note
Forproperoperatingperformanceusing
open-orclosed-looppressureorowcontrol,
theProControl1KEPlusFluidPressureI/P
Transducermustoperateatanoutletair
pressureofatleast10psi(0.7bar).When
using1:1air-operateduidregulators,this
meansthattheminimumpressuredrop
betweenthe1KEuidoutletandthegun
nozzleisatleast10psi(0.7bar)duringthe
expectedsprayconditions(owrateranges)
andmaterialviscositiesthatwillbeused.If
thebackpressuredropsbelow7psi(0.5bar),
theperformancemaybecomeinconsistent.
Backpressurecanbeincreasedbyusing
asmallerdiameteruidhoseoralonger
hosebetweenthe1KEPlusandthespray
gun.Analternatesolutionwouldbetousea
Graco24E4711:2RatioFluidRegulatorora
24E4721:3FluidRegulator,seeinstruction
manual3A0427fordetails.Thesealternate
ratiouidregulatorshaveloweruidoutlet
pressureranges,butwillallowthe1KEPlus
FluidPressureI/PTransducertooperateat
ahigheraircontrolpressure.
Note
Iftheapplicationrequiresgreaterthan50psi
(3.5bar)ofuidpressureattheProControl
1KEPlusoutlet,youmustuseeither16V680
non-hazardouslocationpowersupply
moduleorthe26C724G-Barrierhazardous
locationpowersupplymodule.The16M167
hazardouslocationpowersupplymodule
outputislimitedandwillnotdrivetheuid
pressureI/Ptransducertogreaterthan50
psi(3.5bar).