AppendixA-ModbusVariableMap
Run Run
Run
Registers Registers
Registers
Allregistersare32-bit.
Address Address
Address
Description Description
Description
Permissions Permissions
Permissions
Units Units
Units
Low Low
Low
High High
High
Notes Notes
Notes
402000Date,YearRead/WriteYY199Limitedto2099
402002Date,MonthRead/WriteMM112
402004Date,DayRead/WriteDD131
402006Time,HourRead/WriteHH023
402008Time,MinuteRead/WriteMM059
402010
Time,Second
Read/Write
SS
059
402012AlarmsNeeding
Acknowledgment
Read/Write
Biteld
032-bit
SeeAlarmBiteld
Table,page83
402014
CurrentGrandTotal
Read
cc
032-bit
402016
CurrentBatchTotal
Read/Write
cc
0999999Write0toreset
402018
CurrentMaintenanceTotal
Read/Write
cc
09999999Write0toreset
402020
CurrentFlowRate
Readcc/min065535
402022
CurrentPressure
Readbar032-bit
Scaledas1bar=
65536
402024Unused
402026
CalibrationMode
Read/WriteBit01
0=Off
1=On
402028
Calibration,Measured
Volume
Read/Write
cc
032-bit
402030
Calibration,Actual
DispensedVolume
Read/Write
cc
032-bit
402032DispenseModeRead/Write
Selection
03
0=Standby
1=Flush
2=Fill
3=Dispense
402034
GunTriggerOnTime
Read
ms
032-bit
402036
CurrentJobSprayTotal
Read
cc
024-bit
402038
CurrentJobFlushTotal
Read
cc
024-bit
402040
CurrentJobNumber
Read/WriteValue032-bitAutomatically
increments
402042JobAttributeRead/WriteValue032-bit
Useforidentication
oftheuser,station,
part,etc.
402044
JobGunTriggerTime
Read
ms
032-bit
402046Unused
402048Unused
823A6948A