Page #57 background imageLoading...
Page #57 background image
DeviationsandAdvisories
Deviations Deviations
Deviations
and and
and
Advisories Advisories
Advisories
Code Code
Code
Icon Icon
Icon
Summary Summary
Summary
Description Description
Description
Solution Solution
Solution
SN
Minimum
Fill
Volume
Alarmonly.Activewhenthe
user-set󰘰llvolumeisnotachieved
ina󰘰llcycle.
Increase󰘰lldrivepercentage,
󰘰lltime,orcheck󰘱uidsupply
(SetupScreen10:PIDData,page51).
Press
toclearalarm.
SP
Minimum
Flush
Volume
Alarmonly.Activewhenthe
user-set󰘱ushvolumeisnot
achievedina󰘱ushcycle.
Increase󰘱ushdrivepercentage,
󰘱ushtime,orcheck󰘱uidsupply
(SetupScreen11:FillMode,page51).
Press
toclearalarm.
B4 Job
Dispense
High
Alarmonly.Activewhenthe
loggedjobsprayvolumeismore
thanthethresholdsetpoint.
Adjust󰘱owrate,spraytime,maximum
volumelimit,ordisablealarm
(SetupScreen1:JobTarget,page43).
Press
toclearalarm.
B1 Job
Dispense
Low
Alarmonly.Activewhenthe
loggedjobsprayvolumeisless
thanthethresholdsetpoint.
Adjust󰘱owrate,spraytime,minimum
volumelimit,ordisablealarm
(SetupScreen1:JobTarget,page43).
Press
toclearalarm.
F6 Runaway
Flow
Deviationonly.Activewhenusing
󰘱owcontrolandthe󰘱owtargetis
notachievable.
Determinecauseof󰘱uidcontrolfailure.
Press toclearalarm.
P6 Runaway
Pressure
Deviationonly.Activewhenusing
pressureor󰘱owcontrolandthe
pressuretargetisnotachievable.
Determinecauseof󰘱uidcontrolfailure.
Press
toclearalarm.
EU
System
Idle
Advisoryonly.Activewhenin
Dispensemodeandthegun
triggerhasnotbeenactivatedfor
theuser-settimeouttime.Fluid
pressureisdroppedtozero.
Dispensepressurewillresumeimmediately
oncetheguntriggerisactivated.The
advisorywillautomaticallyclear.Press
toclearalarm.
MF Mainte-
nance
Counter
Advisoryonly.Activewhenthe
maintenancetotalizerreachesthe
user-setmaintenancetarget.
Performmaintenance.Resettozero
using
(SetupScreen2:Maintenance
Totalizer,page44).Press toclear
alarm.
G2 GunOff
Setpoint
Advisoryonly.The󰘱owrate
setpointwaschangedtoalower
valuewhilethegunwasoff.
Insteadofpredictingapressure
target,thesystemwillpredicta
currentoutputtargettotheI/P.It
maytakeextratimetostabilizein
thissituation.
Activatespraying.Press
toclearalarm.
3A6948A57

Table of Contents

Other manuals for Graco ProControl 1KE Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco ProControl 1KE Plus and is the answer not in the manual?

Graco ProControl 1KE Plus Specifications

General IconGeneral
BrandGraco
ModelProControl 1KE Plus
CategoryControl Unit
LanguageEnglish

Related product manuals