Pressure Relief Procedure
28 312062A
Pressure Relief Procedure
1. Relieve pressure in gun and perform gun shutdown
procedure. See gun manual.
2. Close gun fluid manifold valves A and B.
3. Shut off feed pumps and agitator, if used.
4. Turn PRESSURE RELIEF/SPRAY valves (SA, SB)
to PRESSURE RELIEF/CIRCULATION . Route
fluid to waste containers or supply tanks. Ensure
gauges drop to 0.
5. Engage gun piston safety lock.
6. Disconnect gun air line and remove gun fluid mani-
fold.
ti2421a