Spray
3A2776K 41
9. Open recirculation valves.
10. Ensure metering pump air regulator (CD) is turned
counterclockwise to 0 psi.
For hazardous location models, do not turn off the main
power switch (CA). If air is blocked, turned off, or
depressurized the system will turn off. To turn on
system, open the main power switch (CA) and allow the
3 minute purge sequence to complete.
11. At the main run (fluid control) screen, press to
enter manual pump run mode.
12. Press repeatedly to select . Press to
begin circulating.
13. Use metering pump air regulator (CD) to slowly
increase the air pressure to the metering pumps
until the enabled pump(s) begin running slowly.
For Hazardous Location Models: the system on/off valve
is already open.
14. Turn A and B tank fluid heater (BB) ON if it isn’t
already ON.
15. To adjust tank fluid heater temperature, adjust the
numbered knob on the heater.
16. Turn on the primary material heaters.
a. Navigate to the Supply screen. See Operator
Command Mode Screens on page 75.
b. Press and to turn on the A and B
primary heaters, and press to turn on the
hose bundle heater.
NOTICE
Run metering pump as slowly as possible until it is
fully primed to prevent pump damage due to pump
cavitation.
Non-Hazardous
Location
BB
BB