Loading...
Color Change
312779E 113
F
IG
. 125: Color Change Chart 17
Valve Time-Sequence
Dump A A
Dump B B
Color Change Solvent
Catalyst Change Solvent
Color Change A A A
Catalyst Change B B B
Air Purge
Solvent Purge
3rd Flush Purge
*Exiting Fill
Dispense A A A
Dispense B BB
Gun Trigger(s) by Operator
012 3
*Exitin
g
Fill Time 0->2
Color Fill Time 0->1
Catalyst Fill Time 1->2
Mixed Fill Time 2->3
Notes: Load tables from new recipe
Mixed Material Purge Timers from old recipe
CC Purge/Fill Timers and Mixed Fill Time from new recipe
*Exiting Fill Source and Length are Programmable
ProMix 2KS Recipe Change
Chart 17: Recipe 0 OR 61 to Recipe X with Dump Valves and 3rd Flush Valve
Mixed Fill Time does not
begin until the Exiting Fill
Time and Color/Catalyst Fill
Time is complete.
F
IG
. 126: Color Change Chart 18
Valve Time-Sequence
Dump A A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A A A
Catalyst Change B
Air Purge
Solvent Purge
3rd Flush Purge
*Exiting Fill
Dispense A A A A
Dispense B BB
Gun Trigger(s) by Operator
012 3
*Exiting Fill Time 0->1
Color Fill Time 1->2
Mixed Fill Time 2->3
Notes: Load tables from new recipe
Mixed Material Purge Timers from old recipe
CC Purge/Fill Timers and Mixed Fill Time from new recipe
*Exiting Fill Source and Length are Programmable
ProMix 2KS Recipe Change
Chart 18: Recipe 0 OR 61 to Recipe X without Dump Valves and 3rd Flush Valve