Spraying
3A9014A 19
Clear Tip Clogs
In the event debris clogs the Spray Tip, the
sprayer is designed with a reversible Spray
Tip that quickly and easily clears the particles
without disassembling the sprayer.
1. Turn Prime Knob down to PRIME
position to relieve system pressure.
2. Reverse Spray Tip to UNCLOG position.
3. Set Speed Control to highest available
setting.
4. Point sprayer into waste pail, turn Prime
Knob forward to SPRAY position. Pull
Trigger for 5 seconds to clear clog.
NOTE: If Spray Tip is still clogged, you may
have to repeat steps 1-4, or replace with
replacement Spray Tip.
5.
Turn Prime Knob downward to PRIME
position.
Rotate Spray Tip back to
SPRAY position. Turn Prime Knob
forward to SPRAY position, and resume
spraying.
To avoid serious injury from skin injection,
do not put your hand in front of the Spray
Tip when installing or removing the Spray
Tip and Tip Guard.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco TrueCoat 360 VSP and is the answer not in the manual?

Graco TrueCoat 360 VSP Specifications

General IconGeneral
Power SourceElectric
Adjustable SpeedYes
Voltage120V
Spray PatternAdjustable
Nozzle Sizes Included1
Adjustable PressureYes
TypeAirless
Tip Size0.015 inches
Orifice Size0.015 inches
MaterialPlastic, Metal
Spray Tip Sizes Included0.015 inch

Related product manuals