360 EXPRESS
8–11
Connecting The Dockside Power
(Either Shore 1 or Shore 2)
1). Verify that the external power source is a 3 wire grounded system with amperage and
voltage ratings compatible with the boat’s AC system ratings.
2). Be sure there is sufficient cable length to allow for normal movement between the boat and
the dock.
3). Turn all AC panel switches (including the appropriate distribution switch) to the off
position. Turn the circuit breaker under the starboard deckwing to off. Turn the circuit
breaker at the dock outlet to off.
4). Connect the dockside power cable at the boat inlet first.
5). Connect the dockside power cable at the dock outlet and turn the dock outlet circuit breaker
to on.
6). Turn the circuit breaker under the starboard deckwing to the on position.
7). Turn the appropriate distribution switch to the on position.
Disconnecting The Dockside Power
(Either Shore 1 or Shore 2)
1). Switch all circuit breakers at the boat’s AC panel off (including the appropriate distribution
switch).
2). Switch the circuit breaker under the starboard deckwing off.
3). Switch the circuit breaker off at the dock outlet.
4). Disconnect the dockside power cable at the dock outlet first.
5). Disconnect the dockside power cable at the boat inlet.
GENERATOR
The generator option enables you to use AC accessories without being attached to shore
power. The diesel generator is a Fischer Panda™ 8 Mini, capable of producing 7500 peak watts
and a constant 6800 watts. The generator diesel fuel is supplied by a separate tank located in the
aft rigging area. See “Generator Layout” on page 8–36 for a layout of the generator system.
Generator Control Panel
The generator control panel is located in the cabin at the bottom of the AC/DC panel. This
panel is equipped with some monitoring functions. To learn more about these monitoring
functions, reference the Fischer Panda owners manual included in your owners packet.
W A R N I N G
If the reverse polarity indicator on the AC panel is activated, immediately disconnect the dockside
power cable, and have a qualified electrician correct the fault.
N O T I C E
Keep inlet covers closed tightly when not in use.
!