EasyManuals Logo
Home>Grandstream Networks>IP Phone>GRP2616

Grandstream Networks GRP2616 Administration Guide

Grandstream Networks GRP2616
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
GRP2600 Administration Guide
Version 1.0.5.15
P a g e | 96
Firmware
Firmware Upgrade
Via
Allows users to choose the firmware upgrade method:
TFTP, FTP, FTPS, HTTP or HTTPS. The default setting is “HTTP”.
Firmware Server
Path
Defines the server path for the firmware server.
Firmware
HTTP/HTTPS User
Name
The user name for the HTTP/HTTPS server.
Firmware
HTTP/HTTPS
Password
The password for the HTTP/HTTPS server.
Firmware File Prefix
Enables your ITSP to lock firmware updates. If configured, only the firmware
with the matching encrypted prefix will be downloaded and flashed into the
phone.
Firmware File
Postfix
Enables your ITSP to lock firmware updates. If configured, only the firmware
with the matching encrypted postfix will be downloaded and flashed into the
phone.
Maintenance Syslog
Syslog Protocol
If set to SSL/TLS, the syslog messages will be sent through secured TLS
protocol to syslog server.
Default setting is UDP.
Note: The CA certificate is required to connect with the TLS server.
Syslog Server
The URL or IP address of the syslog server for the phone to send syslog to.
Note: By adding port number to the Syslog server field (i.e 172.18.1.1:1000),
the phone will send syslog to the corresponding port of that IP.
Syslog Level
Selects the level of logging for syslog.
The default setting is None. There are 4 levels: DEBUG, INFO, WARNING
and ERROR.
Syslog messages are sent based on the following events:
Product model/version on boot up (INFO level);
NAT related info (INFO level);
sent or received SIP message (DEBUG level);
SIP message summary (INFO level);
inbound and outbound calls (INFO level);
registration status change (INFO level);
negotiated codec (INFO level);
Ethernet link up (INFO level);
SLIC chip exception (WARNING and ERROR levels);
Memory exception (ERROR level).

Table of Contents

Other manuals for Grandstream Networks GRP2616

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks GRP2616 and is the answer not in the manual?

Grandstream Networks GRP2616 Specifications

General IconGeneral
BrandGrandstream Networks
ModelGRP2616
CategoryIP Phone
LanguageEnglish

Related product manuals