CE6000-UM-251-9370 7-9
7 ELECTRICAL ADJUSTMENTS
7.7 Adjusting the Pen Force
This adjustment will set the pen force.
If you replace the main board, use the following procedure to input the recorded adjustment values.
If you replace the pen block assembly, you must measure the pen force by using the
Correx Dial Tension
gauge (50,300,500 gf) and adjust pen force to the target force with following procedure.
How to adjust the pen force
(1) Put into a 0.9 mm diameters cutter blade holder to the tool holder. (The blade length should be 0. Do
not turn out the blade from the blade holder.)
(2) Load a sheet of paper into the plotter.
(3) Turn on the power while pressing the FAST and the ENTER keys.
(4) Select the Language and the Length Unit if the Language selection menu is displayed (See section
7.5.).
(5) Press the PAUSE/MENU key at the following menu.
(6) The following menu is displayed, and then press the right arrow key (ADJ).
(7) The following menu is displayed.
(8) Press the F2 key (PEN FORCE) to display the following menu.
(9) Press the F2 key (MANUAL) to display the following menu.
Note: Do not press the F1 key (Auto with gauger). This mode is used in production.