9 TROUBLESHOOTING
9.6 ARMS Error Messages
Error
Code
LCD Display Cause Solution
E04001
Tilt to adjust with AXIS
ALIGNMENT is too large.
Reload the media.
E04002
It is over the setting range of the
distance adjust.
Reset to smaller value.
E04003
Failed to adjust the sensor level. This media cannot be used.
E04004
It is over the setting range of the
distance adjust.
Reset to smaller value.
E04005
Could not scan the registration
marks.
Check the registration scan
position.
E04006
Amount of data has exceeded the
I/O buffer size for the segment
area registration mark.
Decrease the data size.
E04007
Test pattern plotting position is not
within the plotting area for sensor
position adjustment.
Move the media toward center
and plot the test pattern.
E04008
Media end was detected while
detecting the registration mark.
Check the media. Check the print
position of the registration mark.
E04009
It has exceeded detection area
while detecting the registration
mark.
Check the media. Check the print
position of the registration mark.
E04010
It has exceeded detection area
while detecting the registration
mark.
Check the media. Check the print
position of the registration mark.
E04011
It has exceeded detection area
while detecting the registration
mark.
Check the media. Check the print
position of the registration mark.
E04012
It has exceeded detection area
while detecting the registration
mark.
Check the media. Check the print
position of the registration mark.
E04013
It has exceeded detection area
while detecting the registration
mark.
Check the media. Check the print
position of the registration mark.