CE6000-UM-251-9370 7-11
7 ELECTRICAL ADJUSTMENTS
(12) Similarly, adjust the 120 g-pen force as like as step 10.
Press the ENTER key if the measured value is within the specication range (120±10 g).
Press the ENTER key if you have input the recorded value.
The next specied pen force appears.
(13) Similarly, adjust the 305 g-pen force as like as step 10.
Press the ENTER key if the measured value is within the specication range (305±20 g).
Press the ENTER key if you have input the recorded value.
The next specied pen force appears.
(14) Similarly, adjust the 458 g-pen force as like as step 10.
Press the ENTER key if the measured value is within the specication range (458±20 g).
Press the ENTER key if you have input the recorded value.
(15) The following menu is displayed.
(16) Turn off the power when above menu is displayed.
Note: When adjusting the pen force, it is important to do it quickly. Delaying the pen force adjustment
changes the temperature of the actuator and causes articially lower readings. When this
happens the actual pen force may be higher than the specication. This is especially true for
the upper pen force adjustment.
Specication of the actual pen force
Specied pen force Actual force range
10 g 8 to 12 g
40 g 36 to 44 g
120 g 110 to 130 g
305 g 285 to 325 g
458 g 438 to 478 g
Note: The “ENCODER ERROR” is displayed when starting the pen force adjustment if the blade
holder is not set to the tool holder and the adjustment value is low at 10 g force adjustment.
Set the blade holder to the tool holder and then adjust the pen force.