CE7000-UM-251-9370 8-14
8 Electrical Adjustment
(7) Return the SW1 setting to the normal mode as shown below.
Dip Switch (SW1) 1 2 3 4 5 6 7 8 Model
12345678
ON
OFF
OFF OFF OFF OFF OFF OFF OFF OFF CE7000-40
12345678
ON
OFF
ON OFF OFF OFF OFF OFF OFF OFF CE7000-60
12345678
ON
OFF
OFF ON OFF OFF OFF OFF OFF OFF CE7000-130
12345678
ON
OFF
ON ON OFF OFF OFF OFF OFF OFF CE7000-160
12345678
ON
OFF
OFF ON ON OFF OFF OFF OFF OFF CE7000-130AP