CE7000-UM-251-9370 7-64
7 DISASSEMBLY AND REASSEMBLY
7.4 Conrming the cable wiring
When the cables were reconnecting to the connector, conrm each cables are connected correctly.
Specially conrm the following cables are reconnected correctly.
The cables from the X-motor to the main board.
The cables from the Y-motor to the main board.
The exible cable (Cam sensor exible cable) from the cam sensor board to the main board.
The exible cable (Y exible cable) from the Y relay board to the main board.
The exible cable (Control panel exible cable) from the control panel board to the main board.
Conrming the cables wiring from the X-motor to the main board
The cables for X and Y motor has same connectors, therefore do not connect those cables incorrectly.
The X motor has the power cable and the encoder cable, connect these cables to correct connectors as
shown in the picture below.
CE7000-130/130AP/160CE7000-40/60
Main board
X motor
X motor power cable
X motor encoder cable
X motor